Protection Features
OCP12V: 76.944A (124.1%), 11.998V
5V: 34.5A (138%), 4.86V
3.3V: 31.2A (124.8%), 3.23V
5VSB: 5A (166.67%), 4.996V
OPP923.17W (123.09%)
OTP✓ (75°C @ secondary side)
SCP12V: ✓
5V: ✓
3.3V: ✓
5VSB: ✓
-12V: ✓
PWR_OKOperates properly
NLO
SIPSurge: MOV
Inrush: NTC thermistor & bypass relay

Over-current protection on the minor rails is set at normal levels, while the 5VSB rail can deliver lots of power before its corresponding protection kicks in.

The low over-temperature protection, restricted at 75°C, is particularly notable. Normally, a 50°C-rated PSU would have a much higher OTP triggering point.

Finally, the power-good signal is accurate, and the platform is equipped with surge and inrush current protection.